Browse all practice questions for the Florida Journeyman Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Florida Journeyman Practice Exam 2026 - Free Journeyman Practice Questions and Study Guide course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • A thermostat is a device that detects what condition?
  • What happens if the testing gas is not properly removed from a refrigerant system?
  • In a medium temperature application, how can heat transfer resistance in the evaporator be reduced?
  • Which of the following factors is NOT a consideration in ventilation systems?
  • What type of device uses a RCD to prevent electrical shock?
  • Which of the following is not an indication of a partial restriction on the high side of the refrigeration system?
  • Which Florida agency oversees licensing for electrical contractors?
  • Gas equipment is installed on a roof 4 feet from the edge of the roof, how high must the railing be?
  • According to regulations, the return air from a dwelling unit shall not be discharged through the cooling system to what?
  • What is the function of a fuse in an electrical system?
  • Combustion air supply is required for which type of equipment?
  • Which valve is used to control the gas supply to the burners during operation of an appliance?
  • Which of the following is not acceptable material for the base of a boiler?
  • What impact does reducing the airflow across the evaporator have on the system?
  • Drainage and overflow from cooling towers and evaporated condensers may discharge into which of these areas?
  • What is the minimum area for vertical ducts delivering outside combustion air to a 45,000 BTU/h rated water heater?
  • A refrigerant system that has been improperly pressure-tested could lead to what type of operational issue?
  • Which type of duct is typically used for exhaust purposes in commercial kitchens?
  • What should be considered when installing outdoor wiring?
  • What effect does a thermostatic expansion valve with a discharge power element have on the evaporator?
  • Why must liquid and suction line piping be sized large enough?
  • Where should the main burner of a gas-fired boiler have an approved manual shut-off valve installed?
  • Residential gas furnaces may be vented with single wall vent piping under all conditions except?
  • What is the purpose of the bleed port in a thermostatic expansion valve?
  • What type of wire is typically used for residential wiring?
  • Which substance should not be used for safety reasons within a refrigerant system for testing?
  • An established and recognized agency regularly engaged in conducting tests of furnishing inspection services when such agency has been approved by the building official is called?
  • What type of device protects sensitive electronics from power surges?
  • What is an acceptable method for scavenging the combustion chamber and breaching of a boiler?
  • Condensate drain piping shall not be installed with a slope of less than?
  • What is the standard height for light switches in residential buildings?
  • What is the primary material used for electrical panel grounding?
  • What does the term "overcurrent" mean?
  • What is the minimum width of a discharge opening for a grease duct serving a type one hood?
  • When an appliance with a combustible chamber is located in the same room as a ventilation system return air opening, how close should the return air be to the open combustion?
  • What is the maximum height for outdoor lighting installations?
  • What instrument is used to measure airflow velocity?
  • If an appliance is installed to its listed clearance, what will the installation be considered?
  • What is the function of a grounding electrode system?
  • What is the minimum spacing between rung cleats or steps of a fixed ladder at a construction site?
  • What defines a "dedicated circuit"?
  • What should be monitored to ensure safe operation of gas-fired boilers?
  • Which of the following is not a type of electrical wiring?
  • For safety reasons, which gas should not be used for testing refrigerant systems?
  • Absorption systems use which type of refrigerant for better efficiency in certain conditions?
  • Which of the following is not a main type of automatic refrigerant flow control?
  • Which issues might originate from a compressor operating at reduced volumetric efficiency?
  • How does a contactor operate?
  • What type of pressure does an evaporator usually operate under?
  • What is the primary purpose of grounding in electrical systems?
  • In refrigerant systems, excessive nitrogen can lead to which condition?
  • A duct serving a type one grease hood that penetrates a ceiling, wall, or floor should be enclosed in a duct enclosure from which point?
  • What color identifies a grounded conductor in electrical wiring?
  • What type of screen is required for air inlets from outside the building serving residential occupancies?
  • Which gas is commonly used for pressure testing refrigerant systems due to its safety?
  • What is the minimum thickness required for Type I commercial hoods made of stainless steel?
  • What is a typical sign of a starved evaporator?
  • A vertical duct delivers outside combustion air to a water heater. What is the minimum area of each duct if the water heater is rated at 45,000 btuh?
  • What is the maximum height of a surface that an employee can work or walk above an adjoining?
  • What is the minimum unobstructed access width that must be provided on all sides of a boiler?
  • Which of the following is not a requirement for an air dispersion system?
  • Which code specifies the standards for ventilation supply air?
  • What is a common effect of high pressure in the high side of a refrigeration system?
  • What size breaker is required for a 12-gauge copper wire?
  • In a medium temperature application, the major resistance to heat transfer in the evaporator is the film of refrigerant oil. How may this be reduced?
  • What is the primary purpose of a ventilation system in a commercial kitchen?
  • In a machinery room containing mechanical refrigerating equipment, what is the minimum distance required between the machinery room exhaust discharge and the exterior door or window?
  • What is the safe distance for installing outdoor electrical wiring above the ground?
  • What type of ventilating equipment can be transported easily without dismantling and is not connected to a duct?
  • Which component is typically used to interrupt power in an electrical service?
  • What is an electrical discharge?
  • Absorption refrigerating systems must not be located less than 20 feet from a door window or ventilating air inlet to any building unless what condition is met?
  • The components of a refrigeration system under evaporator pressure are referred to as what?
  • What does GFCI stand for in electrical systems?
  • Boilers shall be tested for carbon monoxide to what maximum level?
  • What is the primary function of a receiver in a refrigerant system?
  • Which factor is not considered in ventilation systems?
  • What is the required depth for underground electrical service conductors?
  • What is the primary function of circuit breakers in electrical systems?
  • What is the main benefit of a low water cutoff switch for a boiler?
  • All of the following are indications of partial restriction on high side except?
  • Which procedure is crucial before performing maintenance on a refrigeration system?
  • What is the purpose of a transformer?
  • How often must residential smoke alarms be tested?
  • What is the main advantage of using LED lighting?
  • Why is it important to maintain proper distances from exhaust discharges in machinery rooms?
  • What would disallow duct from penetrating a third floor without a fire damper?
  • What should be used to cover air inlets from outside the building serving residential occupancies?
  • To check electrical circuits, how is a voltmeter usually connected?
  • How high should the pan of batten seam roofs be turned?
  • What is the primary function of a thermostatic expansion valve in a refrigerant system?
  • What is typically used to limit the amount of current flowing in a circuit?
  • In what conditions can electricians work on energized circuits?
  • What does adjusting the superheat primarily affect in a refrigeration system?
  • What condition does a low water cutoff aim to prevent in a boiler?
  • What could be caused by high head pressure in a refrigerant system?
  • What does NEC stand for in the context of electrical standards?
  • What is the minimum thickness needed for a 14-inch round sheet metal duct used in a residence?
  • In a ducted system with a cooling coil installed and an existing furnace heat exchanger, where must the air first flow through according to code?
  • What is the difference between series and parallel circuits?
  • Insulation applied to an exterior surface of ducts in buildings other than dwelling or apartments shall have a flame spread rating of not more than?
  • In refrigerant systems, which system component governs the rate of refrigerant flow?
  • A boiler furnishing steam air pressures in excess of 15 psi is classified as what?
  • When are junction boxes required in residential wiring?
  • When removing any group 1 refrigerant except CO2 from a refrigeration system, how should it be discharged?
  • What is the minimum level of insulation required for a portion of supply duct greater than 3 inches in diameter on the exterior of a residential structure?
  • What is the rated lifespan for most incandescent light bulbs?
  • Which of the following shall not be used for safety reasons within a refrigerant system for testing?
  • How many ohms is considered a low-resistance connection?
  • What does the term "ampacity" refer to?
  • What is the primary function of a transformer?
  • Which of the following is not a main type of automatic refrigeration flow control?
  • What code must all new electrical installations comply with?
  • What is the minimum ampacity requirement for home branch circuits?
  • Where shall the main burner of a gas fired boiler have an approved manual shut off valve installed?
  • If a user finds that their refrigerant system is oversaturated, what is a likely contributing factor?
  • Why is it important to label circuit breakers in an electrical panel?
  • What electrical code section deals specifically with residential wiring?
  • What does a wattmeter measure?
  • Condensate drain piping shall not be installed with a slope of less than?
  • What is the minimum clearance to combustible materials for a duct system operating between 125 degrees and 250 degrees?
  • What type of space is indirectly cooled and enclosed within the building's thermal envelope?
  • What size wire is typically used for a 30-amp circuit?
  • What is the outside sheet metal size of an insulated duct with an airside dimension of 18"x10" and 1" insulation?
  • What is an ampere?
  • How often must a residential electrical panel be inspected?
  • What type of equipment cools by evaporation of water into an Airstream?
  • Which of the following is a primary function of an air handling unit in ventilation systems?
  • What is the minimum thickness required for a 14" round sheet metal duct used in a residence?
  • If a compressor has a displacement of 10 cubic inches but actually pumps 6 cubic inches, what is its volumetric efficiency?
  • What is a common indication of electrical overload?
  • An emergency refrigeration control switch is required to shut off all electrically operated machinery in what type of room?
  • What is the minimum clearance required for overhead service wires over residential properties?
  • Where must smoke alarms be installed in a home?
  • What is required for every electrical service according to Florida code?
  • An outside air inlet for a non-residential portion of a building can have a screen with openings but must be smaller than what size?
  • What is the normal procedure for checking electrical circuits?
  • Which of these tapes is acceptable as a closure system for fibrous glass ductboard?
  • What is the function of a relay in an electrical circuit?
  • What is required for every automatic hot water heating boiler not under continuous attendance?
  • What is the minimum clearance from a grease duct system to combustible material?
  • What must every fuel-burning heating appliance bear on a permanent and legible factory-applied nameplate?
  • What is the purpose of a ground fault circuit interrupter (GFCI)?
  • What is the residential service voltage in most Florida homes?
  • Which material is most commonly used for electrical conduit?
  • Which type of lighting should be used in damp environments?
  • Which statement about hearing protection for employees is true?
  • Which of these tapes is acceptable as a closure system for fibrous glass duct board?
  • What kind of ground is typically used for electrical devices in wet locations?
  • What is the minimum clearance required to combustibles for duct systems operating between 125°F and 250°F?
  • What is the minimum number of hours required for Journeyman Electrical Apprenticeship in Florida?
  • Which device is most commonly used for protecting against electrical shocks in wet environments?
  • What is the maximum allowable voltage drop for branch circuits?
  • What happens to the evaporator if a thermostatic expansion valve is oversized for a system?
  • What is the purpose of a surge protective device?
  • Which factors influence the selection of wire sizes in electrical installations?
  • Which of the following is prohibited for mechanical refrigerating systems and portions thereof?
  • According to NEC, how many receptacles are permitted per 20-amp circuit?
  • What is the purpose of using an anemometer in refrigeration systems?
  • What is the purpose of bonding in electrical systems?
  • In an attic installation, where must a platform be provided?
  • What type of labeling is required on refrigerant pressure relief devices?
  • How many circuits can be placed on a 20-amp breaker in a residential setting?
  • What is the purpose of a disconnect switch?
  • What is the maximum outlet temperature limit for warm air in a plenum supplied by a furnace?
  • The minimum spacing between rungs, cleats, or steps of a fixed ladder on a construction site shall be?
  • What is the main purpose of a circuit breaker?
  • What must all closed type hot water heating systems, not under continuous attendance, be provided with?
  • An emergency refrigeration controls switch shall be provided to shut off all electrically operated machinery in any machinery room containing a mechanical refrigeration system. What may the switch not shut off?
  • Copper tubing used for refrigerant piping of mechanical refrigeration systems shall be commercially designated as?
  • What is the function of a capacitor in an electrical circuit?
  • What type of equipment operates by cooling through the evaporation of water into the air system?
  • When installing receptacles, what is the required height from the floor?
  • What is a sign of a faulty transformer in an electrical circuit?
  • What does a voltmeter measure?
  • What does the term "conductor" mean in electrical terms?
  • What is the first procedure to perform when starting up a new unit?
  • What is the maximum distance between outlets in a residential kitchen according to the NEC?
  • What electrical hazard is caused by aging wiring or insulation?
  • Which of the following is not a requirement for air dispersion system?
  • Which of the following is not a requirement for a fire damper?
  • What is an established and recognized agency called that is engaged in conducting tests or furnishing inspection services?
  • What is the most serious consequence of not removing all the nitrogen used for pressure testing on an HCFC system?
  • What is the primary role of a surge protector?
  • What is the flame spread rating limit for insulation applied to ducts in buildings other than dwellings or apartments?
  • What can appliance vent connectors and joints be securely joined with?
  • Where must a platform be provided for equipment in an attic installation?
  • What type of exhaust is approved for connection to a 6" flue stack venting a gas-fired furnace?
  • Which of the following is not acceptable material for the base of a boiler?
  • For what purpose is a main disconnect switch installed in an electrical service?
  • What should be the maximum number of lighting fixtures connected to a 20-amp circuit?
  • An outside air inlet serving a nonresidential portion of a building may be covered with a screen. The size of the opening in this screen mesh must be no smaller than what size?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy